https://www.cisco.com/c/dam/en_us/training-events/certifications/professional/ccnp-infographic.pdf
117q | 8 D&D
Please share your expirience
hello, du you have any resources for this Exam Certification????
Quick One : Is there a CCNA Data Center Exam or directly we have CCNP DC ? Thanks.
No there is no more CCNA specialization.
https://www.cisco.com/c/en/us/training-events/training-certifications/certifications.html#~certifications
Thanks.
Hey, is there any lab simulaton question on 350-601 ?
What happens to the default host firmware policy after a Cisco UCS Manager upgrade?
A. It is assigned to all the service profiles that include a host firmware policy.
B. It is replaced by a new default policy without any firmware entries.
C. It is set to match the host firmware policy.
D. It is updated to contain the firmware entries of all the components.
The stated answer is A, but I think it is B.
From “Cisco UCS Manager Firmware Management Guide, Release 3.1”
Recommendations for the Default Host Firmware Policy
“After you upgrade Cisco UCS Manager, a new host firmware policy named “default” is created, and assigned to all services profiles that did not already include a host firmware policy. The default host firmware policy is blank. It does not contain any firmware entries for any components. The default policy is also configured for an immediate reboot rather than waiting for user acknowledgment before rebooting the servers.
answer A says “profiles that include a host firmware policy”
The guide says “profiles that did not already include a host firmware policy”
Anyone have thoughts on this?
The exam has 102 Questions, approximately 96 multiple choice and 6 DnD´s.
No Labs, no Simulations.
please can you share the dump?
Does anyone have DCCOR pdf
Anyone can share the dumps ?
Please dump to me also if you have. Please help send to it_tid @ hot mail . com
Thank you very much in advance.
Hi ALL,
anyone can share dumps for new exam 350-601?
Does anyone know if 117q is valid?
anyone has the latest dump for this one? please share one to sandman0409 at yahoo ? thank you in advance
Hello, does anybody have the dumps for the DCCOR exam? Can you please share kiklence 125 @ gmail . com
Hello
This instead of Ccie written?!
Hello, did anyone take recently the 350-601 exam ??
Any valid dumps ??
Thanks!
does anyone have certification guide?
https://mega.nz/#!PJtTXADb!1c_tQ1dFyNn-VEbrg18t-q6PEc07uDGOvDx9phS36AU
Has anyone taken the exam lately?
Would you please send the dump to me : ahmed2negm @ gmail . com
Hi ppl,
Any recent file or feedback about recent pass takers?
Best regards
hi any one recently pass this exam ? do you have dump?
Due to a major version change, an engineer must perform a software upgrade on a Cisco Nexus Series
switch.
Which two technologies can be implemented to reduce disruptions to the network during the upgrade?
(Choose two.)
A. vPC
B. HSRPC. VDC
C. MLAG
D. PAgP
what is the right answer?and why?
The question above.
A. VPC
B. HSRP
C. VDC
D. MLAG
E. PAgP
A & C is correct!
hi the dump https://mega.nz/folder/DQgQiICZ#PLG-jVsOtCA3DPQEhuWeIA
@maximo:
Q: An engineer wants to create a backup of Cisco UCS Manager for disaster recovery purposes.
B and D.
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter43.html
Full state—A binary file that includes a snapshot of the entire system. You can use the file generated from this backup to restore the system during disaster recovery. This file can restore or rebuild the configuration on the original fabric interconnect, or recreate the configuration on a different fabric interconnect. You cannot use this file for an import.
Which statement about the MAC address that the FCoE Initialization Protocol chooses for use by an E-Node in an FCoE implementation is true?
A. The FCoE Initialization Protocol uses a 24-bit FC-MAP and concatenates a 24-bit Fibre Channel ID to create a fabric-provided MAC address.
B. The FCoE Initialization Protocol uses the burned-in MAC address of the converged network adapter for all FCoE operations.
C. FCoE does not use a MAC address. The FCoE Initialization Protocol is used to acquire a Fibre Channel ID, and the address is used for all FCoE communications in the same way as Fibre Channel Protocol.
D. The FCoE Initialization Protocol uses 01.00.0C as the first 24 bits of the MAC address and appends a 24-bit Fibre Channel ID to derive a full 48- bit FCoE MAC address.
Is this a multiple answer question? Seems like this is a single answer question, either A or B.
Anyone can share the dumps ?
Any news ?
@maximo
thanks for sharing all that material.
anyone has the dump?
best regards
Did somebody get any dumps???
Hi all, I just found these dumps;
https://certcollection.org/forums/topic/331553-dumps-350-601-dccor/
Can somebody check if the answers make sense?
This are the dumps
https://mega.nz/folder/DQgQiICZ#PLG-jVsOtCA3DPQEhuWeIA
@ Anonymous,
Which statement about the MAC address that the FCoE…
I think this is a single answer only, which is A. I came across page 431 of the 350-601 Official Cert Guide in reference to this answer.
videos from this 350-601
https://mega.nz/folder/DQgQiICZ#PLG-jVsOtCA3DPQEhuWeIA
Does anybody have dumps for DCACI. Please share
I have found the following community in which people talk about a possible 350-601 dump: https://www.examtopics.com/exams/cisco/350-601
feel free to share your thoughts about it.
On the question above about FCoE and MAC addresses. Seems like 2 options maybe.
Option B might be referring to server-provided Mac addresses SPMA
Option A is fabric provided Mac addresses FPMA
Option A is definitely right. I’d say if tests asks for 2 answers, then AB
Q79 above.
Input can be one command or multiple commands. However, commands that belong to different message types should not be mixed. For example, show commands are cli_show message type and are not supported in cli_conf mode.
examples:
cli_show —>show version ; show interface brief ; show vlan
cli_conf —>interface Eth4/1 ; no shut ; switchport
bash —->cd /bootflash;mkdir new_dir
I can’t seem to verifiy C either. except if NX-API id disabled. The code 400 refers to “invalid cli comand”. So between B and D, i’d say the header is just a name. The body is the command, so I’d go with D.
my reference for this is:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/programmability/guide/b_Cisco_Nexus_9000_Series_NX-OS_Programmability_Guide_7x/NX_API.html
Q79 above, not sure about the body vs header. anyone want to read the link and interpret?
Guys, what is the current dump, how many questions?
Who recently passed the exam? Is the dump being discussed here valid?
Hi guys,
my exam is on 17, anyone can verify if the dump being discussed is valid?
@maximo many thanks for the video course…
Concerning Q79, it concerns programming using Python so you need the CLI module loaded, not the request module. So C should be correct.
The Python programming language uses three APIs that can execute CLI commands. The APIs are available from the Python CLI module.
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/progammability/guide/b-cisco-nexus-9000-series-nx-os-programmability-guide-93x/b-cisco-nexus-9000-series-nx-os-programmability-guide-93x_chapter_0110000.html
Q32:
An engineer is seeking the most optimal on demand CPU performance while configuring the BIOS settings of a UCS C-series rack mount server.
What setting will accomplish this goal?
A. C6 Retention
B. C6 non-Retention
C. C2 state
D. C0/C1 state
Is A the proper answer?
Q32: A not B
B has performance issues until server regains full power